  • Lippert Ground Control 3.0 Out Of Stroke Error
  • The "out of stroke" message on your Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System, # LC358590 means the jack has reached maximum stroke length and can't extend any further to level the trailer. You need to block the legs, I prefer the Ultra-Fab Leveling Blocks for Trailers and RVs, # UF48-979051. If you continue to get an "out of stroke" error or you cannot manually retract the jack then that would point to signs of damaged internals which means the jack leg would need...
    view full answer...

  • Do You Have Any Mounting Brackets to Raise My Rhino-Rack Batwing Awning's Height?
  • I have a solution for you. Unfortunately, there are no particular brackets that will raise your Rhino-Rack Batwing Awning in addition to the brackets you already own. A creative solution for raising your trailer a few inches are leveling blocks like the Ultra-Fab Leveling Blocks for Trailers and RVs # UF48-979051. With the leveling blocks, you will be able to stack the blocks under your trailer's tires in order to raise the overall height of the trailer. This will give your awning a height...
    view full answer...

  • Troubleshooting Out of Stroke Error on LCI Ground Control Auto Leveling System
  • The Out of Stroke error message on the Lippert Ground Control system, such as # LC358590 indicates the jack has extended as far as it will go and has maximized it's extension. To clear the error you can extend all of the jacks in the system at least 6 inches. Then press and hold the retract button until the jacks start to retract. All of the jacks should fully retract and the error should be cleared. You would then either need to move your camper to a more level location so your jacks...
    view full answer...

  • Troubleshooting An Out Of Stroke Error With The Lippert Ground Control 3.0 Leveling System
  • If you're getting this error then you'd want to use more blocks, like part # A10-0918, so that you won't have to extend the legs of your Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System w Touchpad and Remote # LC358590 as far. Even if the ground seems level you could easily be off 3" - 4" and if your already close to maxing out the range then that one side could be just extending past the allowed threshold. Throwing a few blocks down or a larger base pad like # SC88VR would...
    view full answer...

  • Trouble Shooting And Calibration Of Zero Point On Hydraulic Level Up Leveling System
  • The Gear needs to go to the ground so it can in turn lower the front end. If the gear is not touching it will time out or if it runs out of stroke it will time out, to save the motor from burning out. If you press any button during the auto level process the system will stop the auto level process. When you are trying to auto level the system it will try to go through these steps. Front landing gear will retract, lowering the front of the unit below level, stopping, then lifting the front...
    view full answer...

  • How To Fix Out Of Stroke Error When Leveling Camper
  • If you are getting an "Out of Stroke" error message when trying to level the trailer with a Lippert Ground Control Electric 5th Wheel RV Leveling System like part # LC675817 then that means you are most likely trying to extend the jacks further than they are designed to reach. The solution to this problem would be to try and find a more level place to park the trailer but you can also use the Ultra-Fab Leveling Blocks part # UF48-979051 so that the jack legs do not have to extend as far....
    view full answer...

  • What Causes The Lippert Ground Control 3.0 LC358590 To Have An Out Of Stroke Error?
  • I reached out to my contact at Lippert and on your Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System # LC358590 there is not a way to determine the specific jack that caused the out of stroke error. I will say that 99% of the time this error is not due to a part wearing out, but instead is typically due to the ground where the camper is parked not being level. If one jack has to extended multiple inches further that another then it will cause this error, and could be why...
    view full answer...

  • Out of Stroke Error on Lippert Ground Control
  • I am a bit confused by your question as Kwikee does not make trailer jacks but rather trailer steps. If you were instead referring to trailer jacks such as the Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System part # LC358590 then the "out of stroke" error means you have extended the jack too far. If the jack will not retract using the touchpad then you will need to do so manually with the manual override on top or bottom (see photo). If you continue to get an "out of stroke"...
    view full answer...

  • Troubleshooting Lippert Ground Control "Out Of Stroke" Error When Attempting To Level On A Hill
  • The error "out of stroke" will have one of 2 problems associated with the error on the Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System # LC358590. The first issue is that the jacks physically cannot lift any higher. And since you already checked that the jacks are not out of stroke we know that is not the issue. The second issue is due to an overload of power being sent to the jack. This is common if the trailer weighs to much or has to much weight on a particular jack....
    view full answer...

  • What is Out of Stroke Error on Lippert Ground Control System Display
  • If you are getting the "Out of Stroke" message for your Lippert Ground Control 3.0 4-Point # LC358590 or 6-Point # LC675817 then that means that you have an unsecured controller or you have your RV on an uneven or sloped site. The solutions are to check and secure your controller placement, and if that looks good relocate your trailer so that it is on more even ground. If you are uneven ground then you can try using leveling blocks like the Camco FasTen # CAM44512 to fix the issue. Attached...
    view full answer...

  • 2004 Saturn Vue Transmission Overheating While Flat Towing
  • Motor Trend is a very popular automobile magazine with millions of followers. In September of 2008, one of their writers, "Scott Evans", published an article that dealt with the frequent failures associated with the transmissions used in the 2002-2005 Saturn Vue's. The article further explains that such frequent failures caused a widespread class action lawsuit against General Motors (GM) for the transmission's poor performance. Said actions caused a mandatory settlement for all owners...
    view full answer...

  • Troubleshooting Lippert Electric Stabilizer Jack Clicking and Not Raising
  • The clicking you are hearing sounds like a circuit breaker being stripped and auto resetting. This indicates there is either a wiring issue or the motor is drawing more power than it should. Check the ground wire connection at the battery to ensure the connection to the trailer frame is bare metal to metal. I recommend first checking the trailer battery using a multimeter like # PT89ZR. If the voltage is good at the battery, then inspect the wiring leading to the switch. Next test...
    view full answer...

  • Auto Level Operation Of The Lippert Electric Ground Control TT Automatic Leveling System
  • The tongue jack for your Electric Ground Control TT Automatic 5-Point Travel Trailer Leveling System # LC672136 is supposed to lift up so that the other jacks can properly level out your trailer and does require you to go back and lower the tongue jack once the others are set in place.
    view full answer...

  • Troubleshooting Out of Stroke Error for Lippert Ground Control 3.0 Leveling System
  • If you are getting the "Out of Stroke" message for your Lippert Ground Control 3.0 4-Point # LC358590 or 6-Point # LC675817 then that means that you have an unsecured controller or you have your Cyclone Toyhauler on an uneven or sloped site. The solutions are to check and secure your controller placement, and if that looks good relocate your trailer so that it is on more even ground. If you are uneven ground then you can try using leveling blocks like the Camco FasTen # CAM44512 to fix...
    view full answer...

  • What Does the Out of Stroke Error On the Lippert Ground Control System Mean
  • The out of stroke error you are seeing is shown when you have extended the jacks further then they are designed to reach. The solution to this problem would be to try and find a more level place to park the trailer but you can also use the Ultra-Fab Leveling Blocks part # UF48-979051 so that the jack legs do not have to extend as far. The out of stroke error could also be caused by a few other things but if all works as it should save for this then odds are you are just reaching the maximum...
    view full answer...

  • Stroke Error On Lippert Ground Control Stabilization System
  • I checked with Lippert and a stroke error on the Ground Control system, # LC358590, indicates that the jack has or thinks it has been extended as far as it will go. The recommended fixes are to first make sure the jack is ready to operate and nothing is preventing it from doing so or to move the trailer to another location (which would likely not work in this case since it sounds like using the blocks did not work). You may need to reset the system as well by turning off the control pad...
    view full answer...

  • Troubleshooting An E8 Error On A Fogatti RV Tankless Water Heater
  • The E8 error on a Fogatti RV Tankless Water Heater # LSB44FR indicates a wind pressure switch failure. This sensor is there to check that the unit is properly venting out of the exhaust pipe. Most likely the sensor itself is bad but there are a couple of things you can check before reaching out to Fogatti for a warranty call. 1. First check the power and ground. If the unit isn't receiving a full 12 volts or the ground connection isn't secure then the unit could throw up errors or function...
    view full answer...

  • Front Jacks for Lippert Ground Control Don't Level 5th Wheel Trailer
  • Do you get any error code on the controller for the Lippert Ground Control 3.0 # LC675817? Usually that helps to troubleshoot and the manual gives an exact solution for each error code. You might also try resetting the Zero Point Calibration to see if that helps. You can see how to do that on page 19 of the attached instructions. Is the problem that those front jacks aren't working at all, or do they just not go down far enough to level the 5th wheel? If the issue is that the jacks just...
    view full answer...

  • Why Is My Furrion Fireplace Not Staying On, What Can I Do
  • It seems like your fireplace is not displaying an error code when it shuts off. If that is the case, your fireplace could be shutting off for a number of reasons. Your unit is overheating. Check to see if there are obstructions blocking the venting system of your unit. The heating elements are clogged. Ensure your heater is properly cleaned and debris free. Is there a blocked inlet or outlet on your fireplace? Check the inlet and outlet of the heating area and clear any clogs. Please...
    view full answer...

  • Does Reflective Surface of Camco Lights Out Retractable RV Shade Create Heat to Damage Vent Lid
  • I can't say that it's ever been tested but there aren't any reports of the Camco Lights Out RV Retractable Shade, part # CAM42913, causing any damage to a roof vent lid. It does block heat from entering your RV but it doesn't emit its own heat so I can't imagine in anyway that it could.
    view full answer...